TYPDETAIL

Home / Repairs & Existing

Sister Stud at Damaged / Notched Stud - Elevation - typical repairs & existing detail drawing, DWG
Preview of sister stud at damaged / notched stud - elevation. The DWG is fully editable.

Codes and approvals referenced

CRC R602.6)CRC R602.6).

Text on the drawing

BEARING / EXTERIOR WALLS: NOTCH > 25% OR BORE > 40% OF STUD DEPTH REQUIRES SISTER OR STUD SHOE (CRC R602.6). REMOVE AND REPLACE DECAYED STUDS; LOCATE CAUSE OF MOISTURE BEFORE CLOSING WALL. NEW FULL-LENGTH 2X SISTER STUD, SAME SIZE / GRADE AS (E) 10d FACE NAILS @ 8" O.C. STAGGERED (E) STUD, DAMAGED / OVER- NOTCHED (CRC R602.6) (4) 10d TOENAILS TO EA. PLATE 3/4" = 1'-0"