Split Joist / Rafter Repair - Scab Both Sides Detail - typical repairs & existing detail drawing, DWG
Preview of split joist / rafter repair - scab both sides detail. The DWG is fully editable.

Text on the drawing

(E) 2X JOIST / RAFTER NEW 2X SCAB EA. SIDE, SAME DEPTH, GLUE (APA AFG-01) + SCREWS SDS1/4X3 SCREWS @ 6" O.C., STAGGERED, EA. SIDE (ICC-ES) SHORE MEMBER AND JACK SPLIT CLOSED BEFORE SCABBING. FOR SPLITS AT BEARING OR NOTCHES, OR SPLITS LONGER THAN 1/2 MEMBER LENGTH, REPLACE OR SISTER FULL LENGTH (S-RPR-002). (E) SPLIT / CHECK N.T.S.