Stair Connection Repair Notes - typical repairs & existing detail drawing, DWG
Preview of stair connection repair notes. The DWG is fully editable.

Codes and approvals referenced

ASTM A307CBC TABLE 2304.10.2

Text on the drawing

GENERAL NOTES: 1. STRUCTURAL DETAILS SHOWN ARE FOR STAIR CONNECTION REPAIRS UNLESS NOTED OTHERWISE. 2. ALL WORK SHALL CONFORM TO THE 2025 CALIFORNIA BUILDING CODE (CBC) AND APPLICABLE LOCAL AMENDMENTS. 3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE. 4. ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO CONSTRUCTION. 5. STRUCTURAL DRAWINGS INDICATE MINIMUM REQUIREMENTS ONLY. 6. PROVIDE TEMPORARY SUPPORT AND STABILITY FOR THE AFFECTED STAIR AND LANDING BEFORE DISCONNECTING THE STAIR OR REMOVING SUPPORTING FRAMING. COORDINATE TEMPORARY SUPPORT AND REQUIRED EGRESS BEFORE WORK. AFTER EXPOSURE, SUBMIT PHOTOGRAPHS AND FIELD DIMENSIONS TO THE ENGINEER FOR CONFIRMATION OF REPAIR LIMITS AND CONNECTION DETAILS BEFORE INSTALLING REPLACEMENT FRAMING. FASTENING & CONNECTION NOTES: 1. INSTALL ALL FASTENERS IN ACCORDANCE WITH THE STRUCTURAL DETAILS SHOWN. 2. MAINTAIN MINIMUM EDGE DISTANCE, END DISTANCE, AND SPACING PER CODE AND MANUFACTURER REQUIREMENTS. 3. DO NOT INSTALL FASTENERS IN SPLIT, CRACKED, OR DETERIORATED WOOD. REPLACE AFFECTED MEMBERS PRIOR TO FASTENING. 4. PROVIDE TIGHT BEARING AT ALL WOOD-TO-WOOD AND STEEL-TO-WOOD CONTACT SURFACES. 5. DO NOT PACK OUT STRINGER END PLATES OR CONNECTORS. MAINTAIN DIRECT CONTACT WITH SOUND FRAMING. REFER GAPS OR MISALIGNMENT TO ENGINEER BEFORE FASTENING. BOLTS & STEEL CONNECTION NOTES: 1. ALL MACHINE BOLTS SHALL BE ASTM A307 UNLESS NOTED OTHERWISE. 2. PROVIDE STANDARD CUT WASHERS WHERE BOLT HEADS OR NUTS BEAR ON WOOD. 3. BOLT HOLES SHALL BE DRILLED 1/16 INCH LARGER THAN BOLT DIAMETER, U.N.O. DO NOT ENLARGE OR ADD HOLES IN EXISTING STEEL END PLATES WITHOUT ENGINEER'S APPROVAL. 4. TIGHTEN BOLTS SNUG-TIGHT; DO NOT OVER-TIGHTEN TO THE POINT OF CRUSHING WOOD FIBERS. 5. ALL EXPOSED STEEL, FASTENERS, AND CONNECTORS SHALL BE CORROSION-RESISTANT. CARPENTRY/MATERIAL NOTES: 1. WOOD MEMBERS SHALL BE DOUGLAS FIR-LARCH NO. 2 MINIMUM UNLESS NOTED OTHERWISE. 2. PRESSURE-TREATED WOOD SHALL BE USED WHERE MEMBERS ARE EXPOSED TO WEATHER OR IN CONTACT WITH EXTERIOR SURFACES. 3. ALL EXTERIOR FASTENERS AND CONNECTORS SHALL BE HOT-DIPPED GALVANIZED OR STAINLESS STEEL AS REQUIRED. 4. NEWLY EXPOSED WOOD SURFACES RESULTING FROM FIELD CUTTING OR DRILLING SHALL BE TREATED PER MANUFACTURER RECOMMENDATIONS. LOCALIZED LANDING REPAIR NOTES: 1. REMOVE FINISHES AND SHEATHING AS REQUIRED TO EXPOSE THE DAMAGED LANDING FRAMING AT THE STAIR CONNECTION. REPLACE MEMBERS IDENTIFIED AS NEW WITHIN THE LIMITS SHOWN. PROTECT EXISTING CONSTRUCTION TO REMAIN. REPORT ADDITIONAL DETERIORATION TO THE ENGINEER BEFORE EXTENDING DEMOLITION OR PROCEEDING WITH REPAIRS. 2. REPLACEMENT SUBFLOOR SHALL BE 5/8" EXTERIOR GRADE PLYWOOD OR OSB FASTENED TO EXISTING JOISTS PER CBC TABLE 2304.10.2 (TYP.). 3. SUBFLOOR (DECK SHEATHING) NAILING - TYP. FASTEN W/ 8d (0.131" DIA x 2-1/2" LONG), HOT-DIPPED GALVANIZED. EDGE NAILING: 6" O.C. FIELD NAILING: 12" O.C. PROVIDE BLOCKING AT ALL UNSUPPORTED PANEL EDGES. 4. WATERPROOFING: RESTORE CONTINUOUS WATERPROOFING AT ALL AREAS DISTURBED BY THE REPAIR, INCLUDING EDGE FLASHING, PENETRATIONS AND TIE-INS TO EXISTING WATERPROOFING. VERIFY COMPATIBILITY OF THE REPAIR SYSTEM WITH EXISTING MATERIALS. SUBMIT EXTENDED REPAIR LIMITS FOR REVIEW WHERE A WATERTIGHT LOCAL TIE-IN CANNOT BE ACHIEVED. N.T.S.

More repairs & existing details

Infill at Former Garage Door Opening Detail - DWG drawing

Infill at Former Garage Door Opening Detail

Sister Joists - Repair Detail - DWG drawing

Sister Joists - Repair Detail

Fire-Damaged Top Plate Repair Detail - DWG drawing

Fire-Damaged Top Plate Repair Detail

Fire-Damaged Truss Repair Detail - DWG drawing

Fire-Damaged Truss Repair Detail

Fire-Damaged Eave Repair Detail - DWG drawing

Fire-Damaged Eave Repair Detail

Infill at Existing Window Opening Detail - DWG drawing

Infill at Existing Window Opening Detail

Exterior Wall Section - Typical - DWG drawing

Exterior Wall Section - Typical

Ceiling Section - Typical - DWG drawing

Ceiling Section - Typical