Codes and approvals referenced
Text on the drawing
12db 90° HOOK 4db, 2 1/2" MIN. 180° HOOK 6db, 3" MIN. 135° TIE HOOK BAR SIZE MIN. INSIDE BEND DIA. (D) #3 - #8 6db #9 - #11 8db #14, #18 10db TIES / STIRRUPS #3 - #5 4db PER ACI 318-19 TABLES 25.3.1 / 25.3.2. db = NOMINAL BAR DIAMETER. BEND BARS COLD; DO NOT FIELD-BEND BARS PARTIALLY EMBEDDED IN CONCRETE UNLESS APPROVED BY ENGINEER. N.T.S.
More general details

Braced Wall Lines and Panels - CRC R602.10 Detail

Wall Sheathing / Shear Wall Schedule

Common Wire Nail Sizes and Nail Loading Detail

Fireblocking and Draftstopping Detail

Mean Roof Height and Stories Above Grade Detail

Vertical Floor Offset - Shear Transfer Detail

Diaphragm Aspect Ratio and Opening Limits - Plan