TYPDETAIL

Home / Foundations

Stud to Sill Plate Uplift Tie - Section - typical foundations detail drawing, DWG
Preview of stud to sill plate uplift tie - section. The DWG is fully editable.

Codes and approvals referenced

ESR-2613

Text on the drawing

2X6 STUD @ 16" O.C. SSP / DSP STUD-PLATE TIE (ESR-2613) EA. STUD WHERE NOTED, ALL HOLES P.T. SILL W/ A.B. PER PLAN AND 3"X3"X0.229" PLATE WASHERS FOUNDATION PER PLAN COMPLETES UPLIFT PATH FROM ROOF TIES (S-WAL-030) TO FOUNDATION. ANCHOR BOLT SPACING AND PLATE WASHERS PER PLAN FOR UPLIFT. N.T.S.