Text on the drawing
8" MIN. FOOTING DEPTH PER PLAN 'b' 3" CLR. STUD WALL PER PLAN 15/32" WOOD STRUCTURAL PANEL (OR PER S.W. SCHED.) OPTIONAL CURB FINISH SLAB IF NO CURB CONCRETE SLAB & REINFORCING PER PLAN (1) #4 CONT. BAR WHERE CURB OCCURS PRESERVATIVE-TREATED SILL PLATE W/ 5/8" DIA. A.B. @ 48" O.C. W/ 3"X3"X0.229" PLATE WASHERS E.N. 8d @ 6" O.C. SLAB ON GRADE WHERE OCCURS FINISH GRADE #3 STIRRUPS @ 12" O.C. OPTIONAL CONSTRUCTION JOINT A.B. EDGE DISTANCE: 'b' = 2 3/4" FOR 2X6 'b' = 1 3/4" FOR 2X4 ANCHOR W/ HEAVY HEX NUT AT HOLD DOWN CONCRETE GRADE BEAM & REINFORCING PER PLAN N.T.S.
More foundations details

Typical Perimeter Footing Detail

Typical Interior Footing Detail

Typical Non-Bearing Wall to Concrete Slab Detail

Dowel into Existing Concrete Slab Detail

New Footing to Existing Footing Detail

Concrete Footing to Existing Slab Detail

Concrete Slab to Existing Footing Detail