Codes and approvals referenced
Text on the drawing
SIMPSON CS16 STRAP OVER SHEATHING, (11) 8d EA. END, CENTERED ON RIM WSP SHEATHING SIMPSON LTP4 SILL TO RIM @ 48" O.C. (ALT. A35) SIMPSON A35 RIM TO DBL. TOP PLATE @ 48" O.C. 2X6 STUDS @ 16" O.C. 2X6 SILL & STUDS ABOVE STRAP SIZE, NAILING AND SPACING PER SHEAR WALL / HOLDOWN SCHEDULE. CS16 SHOWN IS TYPICAL MIN. AT ENDS. FASTENERS AND ALLOWABLE LOADS PER SIMPSON CATALOG. DO NOT OVERDRIVE NAILS IN STRAP. FLOOR JOISTS W/ RIM N.T.S.