TYPDETAIL

Home / Walls & Shear Walls

Top Plate Cut for Pipe or Duct - Strap Detail - typical walls & shear walls detail drawing, DWG
Preview of top plate cut for pipe or duct - strap detail. The DWG is fully editable.

Codes and approvals referenced

CRC R602.6.1.CS16

Text on the drawing

6" MIN. NAILED CS16 STRAP EA. FACE, (8) 10d EA. SIDE OF CUT PIPE / DUCT THRU PLATE WHERE TOP PLATE IS CUT OR BORED MORE THAN 50% OF WIDTH, PROVIDE STRAP PER CRC R602.6.1. STRAP: 0.054" (16 GA.) X 1-1/2" GALV. STEEL, FASTENED W/ (8) 10d (0.148"X1-1/2") EACH SIDE OF OPENING. N.T.S.