Codes and approvals referenced
Text on the drawing
SIMPSON LSTA24 STRAP ON TOP PLATES W/ (8) 10d EA. SIDE OF SPLICE (2) 2X TOP PLATE, SPLICES OFFSET 24" MIN. (CRC R602.3.2) STUD WALL PER PLAN TOP PLATE SPLICE STRAP REQUIRED AT CHORD / COLLECTOR LINES PER PLAN. CENTER STRAP OVER SPLICE. NAIL HOLES IN SPLICE ZONE MAY BE LEFT EMPTY 1 1/2" EA. SIDE OF JOINT. N.T.S.