Codes and approvals referenced
Text on the drawing
SLOPE DOWN GARAGE DOOR 6" CONCRETE SLAB W/ CONTINUOUS PERIMETER THICKENED END SLAB REINFORCING STEEL AS PER FOUNDATION PLAN 10 MIL. VAPOR BARRIER OR EQUIVALENT PER CRC R506.2.3 6" MIN. PERMEABLE CAPILLARY BREAK (COMPLYING W/ CALTRANS CLASS I TYPE A) 30" MIN. RECOMPACTED ENGINEERED FILL (SHALL EXTEND MIN 3' HORIZONTALLY BEYOND FOUNDATION PERIMETER) 1" EXPANSION JOINT (2) #6 BOTTOM CONT. PROVIDE #3 CLOSED TIES @ 12" O.C. REFER TO TYP. PERIMETER FOOTING FOR DETAILS NOT SHOWN N.T.S.