Typical Perimeter Footing - 3-Story Slab on Grade Detail - typical foundations detail drawing, DWG
Preview of typical perimeter footing - 3-story slab on grade detail. The DWG is fully editable.

Codes and approvals referenced

CRC TABLE R403.1(1)

Text on the drawing

18" MIN. 8" MIN. 12" MIN. 8" MIN. STUD WALL PER PLAN P.T. 2X6 SILL W/ 5/8" DIA. A.B. @ 48" O.C. W/ 3"X3"X0.229" P.W. FINISH GRADE FOOTING SIZE PER CRC TABLE R403.1(1), LIGHT- FRAME CONSTRUCTION, 1500 PSF ALLOWABLE SOIL BEARING U.N.O. VERIFY W/ SOILS REPORT. 4" CONC. SLAB W/ #3 @ 18" O.C. EA. WAY OVER 15 MIL VAPOR RETARDER OVER 4" GRAVEL #4 VERT. @ 48" O.C. W/ STD. HOOK (1) #4 TOP (2) #4 BOTTOM CONT. N.T.S.