Utility Trench Adjacent to Footing Detail - typical foundations detail drawing, DWG
Preview of utility trench adjacent to footing detail. The DWG is fully editable.

Codes and approvals referenced

CPC 314.4

Text on the drawing

TRENCH BOTTOM SHALL NOT EXTEND BELOW 1:2 PLANE FROM FOOTING EDGE UTILITY TRENCH / PIPE FOOTING PER PLAN WHERE TRENCH CANNOT STAY ABOVE 1:2 PLANE, DEEPEN FOOTING OR BACKFILL W/ 2-SACK SLURRY PER ENGINEER. CPC 314.4: TRENCHES PARALLEL TO FOOTINGS SHALL NOT EXTEND INTO BEARING PLANE OF FOOTING. DETAIL # - UTILITY TRENCH ADJACENT TO FOOTING NOT TO SCALE