TYPDETAIL

Home / Walls & Shear Walls

Window Header - 4X10, 5'-0" Maximum Opening Detail - typical walls & shear walls detail drawing, DWG
Preview of window header - 4x10, 5'-0" maximum opening detail. The DWG is fully editable.

Codes and approvals referenced

CRC TABLE R602.7(1)

Text on the drawing

R.O. 5'-0" MAX. 4X10 DF-L NO. 1 HEADER FULL BEARING ON TRIMMERS (2) 2X TOP PLATE, LAP 48" MIN. (1) 2X TRIMMER EA. END 2X KING STUD EA. END, FACE NAIL TO HEADER W/ (4) 16d EA. END (2) 2X FLAT ROUGH SILL 2X CRIPPLES @ 16" O.C. 2X SILL PLATE HEADER SIZED PER CRC TABLE R602.7(1): ROOF + CEILING, 30 PSF SNOW / 20 PSF LL, 28' BLDG. WIDTH, 2X4/2X6 WALL. VERIFY FOR FLOOR LOADS OR GIRDER LOADS W/ ENGINEER. N.T.S.