Codes and approvals referenced
Text on the drawing
E.N. @ ALL PANEL EDGES, 3/8" MIN. FROM EDGE, SPACING PER SCHEDULE FIELD NAILING (F.N.) @ INTERMEDIATE SUPPORTS, 12" O.C. TYP. 1/8" GAP AT ALL PANEL ENDS AND EDGES PANEL STRENGTH AXIS PERP. TO SUPPORTS, END JOINTS STAGGERED 2X FRAMING @ 16" O.C. BLOCK ALL UNSUPPORTED EDGES OF SHEAR WALLS AND BLOCKED DIAPHRAGMS. NAIL SIZE / SPACING PER SHEAR WALL OR DIAPHRAGM SCHEDULE; MIN. PER CRC TABLE R602.3(1). DO NOT OVERDRIVE (CRUSH 1/16" MAX.). 3/8" = 1'-0"
More general details

Braced Wall Lines and Panels - CRC R602.10 Detail

Wall Sheathing / Shear Wall Schedule

Common Wire Nail Sizes and Nail Loading Detail

Fireblocking and Draftstopping Detail

Mean Roof Height and Stories Above Grade Detail

Vertical Floor Offset - Shear Transfer Detail

Diaphragm Aspect Ratio and Opening Limits - Plan