Codes and approvals referenced

ASTM C476ASTM C90

Text on the drawing

48 db MIN. VERT. BAR CENTERED IN CELL, HELD W/ BAR POSITIONERS @ 200 BAR DIA. MAX. (TMS 602) SOLID GROUT CELLS W/ REINF. (ASTM C476) DOWEL W/ STD. 90° HOOK, LAPPED W/ VERT. BAR 8" CMU (ASTM C90) GROUT SPACE 2" x 3" MIN. FOR LIFTS ≤ 5'-4" (TMS 602 TABLE 7). BAR CLEAR TO BLOCK FACE 1/4" MIN. (1/2" FOR COARSE GROUT). LAP LENGTH PER PLAN IF GREATER THAN SHOWN. FOOTING PER PLAN 1" = 1'-0"