2X WOOD JAMB, LAGGED TO CHANNEL INSULATED SECTIONAL DOOR 8" CMU WALL, END CELLS GROUTED PLAN DOOR TRACK AND SPRING LOADS PER DOOR MFR.; JAMB CHANNEL AND STUDS PER STRUCT. FOR LARGE OPENINGS. SEAL JAMB CHANNEL TO CMU W/ SEALANT AND BACKER ROD. C8X11.5 JAMB CHANNEL W/ 1/2" X 6" WELDED STUDS @ 24" O.C. N.T.S.