TYPDETAIL

Home / Masonry

Strap Holdown Anchor in Grouted CMU Detail - typical masonry detail drawing, DWG
Preview of strap holdown anchor in grouted cmu detail. The DWG is fully editable.

Codes and approvals referenced

HDU5SSTB24

Text on the drawing

16" EMBED (2) 2X END POST SIMPSON HDU5-SDS2.5 SIMPSON SSTB24 (5/8") W/ NUT & WASHER, CENTERED IN CELL P.T. 2X6 SILL GROUT SOLID 3 COURSES MIN. AT ANCHOR #5 VERT. EA. SIDE SET ANCHOR W/ TEMPLATE BEFORE GROUTING. 2000 PSI GROUT, CONSOLIDATED. VERIFY CAPACITY W/ SIMPSON MASONRY TABLE FOR THE HOLDOWN SHOWN. N.T.S.