Text on the drawing

ELEVATION 600T125-33 TOP TRACK BOX HEADER, SEE SECTION 600S162-43 KING STUD (2) 600S162-43 JACK STUDS, #8 @ 24" O.C. L2X2X43 MIL CLIP X 8", (4) #8 SCREWS EA. LEG SECTION AT HEADER (2) 1000S162-54, WEBS OUT 600T125-43 TRACK TOP & BOT., #8 @ 24" O.C. EA. LEG HEADER SHOWN FOR 6'-0" MAX. OPENING, ONE FLOOR + ROOF (AISI S230 TABLE); INSULATE CAVITY BEFORE CLOSING. KING AND JACK STUDS FASTENED TOGETHER W/ #8 SCREWS @ 24" O.C. HEAD TRACK SCREWED TO HEADER BOTTOM. N.T.S.