CFS Floor Joist at Foundation Wall Detail - typical cold-formed steel detail drawing, DWG
Preview of cfs floor joist at foundation wall detail. The DWG is fully editable.

Codes and approvals referenced

ASTM A1003ASTM C1513

Text on the drawing

23/32" T&G WSP SUBFLOOR, #8 SCREWS @ 6" O.C. EDGES, 12" FIELD 1000T125-54 RIM TRACK W/ #8 SCREW EA. FLANGE TO JOIST WEB STIFFENER: 362S162-33 X 9 1/2" W/ (4) #8 SCREWS 1000S162-54 JOISTS @ 16" O.C. L3X3X54 MIL CLIP X 6" LONG AT A.B., (4) #10 SCREWS TO JOIST / TRACK 1/2" DIA. A.B. @ 4'-0" O.C., 7" EMBED, 12" FROM ENDS SILL SEALER 8" CONC. FOUNDATION WALL STEEL: ASTM A1003 ST50H (54 MIL & HEAVIER), ST33H (33 / 43 MIL), G60. SCREWS PER ASTM C1513. WEB STIFFENER AT EVERY JOIST BEARING. FLOOR: 40 PSF LIVE + 10 PSF DEAD, SPAN 16'-0" MAX. (AISI S240). N.T.S.

More cold-formed steel details

CFS Continuous Joist over Interior Bearing Wall Detail - DWG drawing

CFS Continuous Joist over Interior Bearing Wall Detail

CFS Lapped Joists over Interior Bearing Wall Detail - DWG drawing

CFS Lapped Joists over Interior Bearing Wall Detail

CFS Cantilevered Floor Joist at Exterior Wall Detail - DWG drawing

CFS Cantilevered Floor Joist at Exterior Wall Detail

CFS Floor Joist Blocking and Strap Bridging Detail - DWG drawing

CFS Floor Joist Blocking and Strap Bridging Detail

CFS Box Header with Jack and King Studs Detail - DWG drawing

CFS Box Header with Jack and King Studs Detail

CFS Roof Rafter at Exterior Wall - Eave Detail - DWG drawing

CFS Roof Rafter at Exterior Wall - Eave Detail

CFS Roof Truss at Exterior Wall Detail - DWG drawing

CFS Roof Truss at Exterior Wall Detail

CFS Roof Rafters at Ridge Beam Detail - DWG drawing

CFS Roof Rafters at Ridge Beam Detail