Text on the drawing
23/32" T&G WSP SUBFLOOR, #8 SCREWS @ 6" / 12" O.C. 1000S162-54 JOIST CONTINUOUS OVER SUPPORT (NO SPLICE) WEB STIFFENER: 362S162-33 W/ (4) #8 SCREWS, CLEAR OF PUNCHOUT #8 SCREW EA. SIDE, JOIST FLANGE TO TOP TRACK 600T125-54 TOP TRACK 600S162-54 BEARING STUDS @ 16" O.C., ALIGNED UNDER JOISTS IN-LINE FRAMING: JOIST CENTERLINE WITHIN 3/4" OF STUD CENTERLINE BELOW (AISI S240 B1.2.3). NO PUNCHOUT WITHIN 10" OF BEARING. BEARING LENGTH 3 1/2" MIN. AT INTERIOR SUPPORTS. N.T.S.