Text on the drawing
8" MIN. LAP 1000S162-54 JOISTS LAPPED BACK TO BACK OVER SUPPORT 23/32" T&G WSP SUBFLOOR (4) #10 SCREWS THRU BOTH WEBS AT LAP #8 SCREW EA. JOIST FLANGE TO TOP TRACK 600T125-54 TOP TRACK 600S162-54 BEARING STUDS @ 16" O.C., ALIGNED UNDER JOISTS LAPPED WEBS ACT AS THE WEB STIFFENER; NO SEPARATE STIFFENER REQUIRED WHERE BOTH JOISTS BEAR FULL WIDTH. SUBFLOOR JOINT NOT TO OCCUR OVER THE LAP OFFSET; SHIM 1 5/8" OFFSET IN LAYOUT AT EA. SPAN. N.T.S.