Text on the drawing

8" MIN. LAP 1000S162-54 JOISTS LAPPED BACK TO BACK OVER SUPPORT 23/32" T&G WSP SUBFLOOR (4) #10 SCREWS THRU BOTH WEBS AT LAP #8 SCREW EA. JOIST FLANGE TO TOP TRACK 600T125-54 TOP TRACK 600S162-54 BEARING STUDS @ 16" O.C., ALIGNED UNDER JOISTS LAPPED WEBS ACT AS THE WEB STIFFENER; NO SEPARATE STIFFENER REQUIRED WHERE BOTH JOISTS BEAR FULL WIDTH. SUBFLOOR JOINT NOT TO OCCUR OVER THE LAP OFFSET; SHIM 1 5/8" OFFSET IN LAYOUT AT EA. SPAN. N.T.S.

More cold-formed steel details

CFS Floor Joist at Foundation Wall Detail - DWG drawing

CFS Floor Joist at Foundation Wall Detail

CFS Continuous Joist over Interior Bearing Wall Detail - DWG drawing

CFS Continuous Joist over Interior Bearing Wall Detail

CFS Cantilevered Floor Joist at Exterior Wall Detail - DWG drawing

CFS Cantilevered Floor Joist at Exterior Wall Detail

CFS Floor Joist Blocking and Strap Bridging Detail - DWG drawing

CFS Floor Joist Blocking and Strap Bridging Detail

CFS Box Header with Jack and King Studs Detail - DWG drawing

CFS Box Header with Jack and King Studs Detail

CFS Roof Rafter at Exterior Wall - Eave Detail - DWG drawing

CFS Roof Rafter at Exterior Wall - Eave Detail

CFS Roof Truss at Exterior Wall Detail - DWG drawing

CFS Roof Truss at Exterior Wall Detail

CFS Roof Rafters at Ridge Beam Detail - DWG drawing

CFS Roof Rafters at Ridge Beam Detail