Text on the drawing
24" MAX. CANTILEVER 600S162-43 STUD WALL ABOVE (ONE STORY + ROOF MAX.) #8 SCREW @ 12" O.C., TRACK THRU SUBFLOOR TO RIM / JOIST 1000T125-54 RIM TRACK (2) 1000S162-54 JOISTS (BACK TO BACK) @ 16" O.C., 6'-0" MIN. BACKSPAN WEB STIFFENER EA. JOIST AT BEARING, (4) #8 SCREWS 600S162-54 STUDS @ 16" O.C. W/ 600T125-54 TOP TRACK SOLID BLOCKING (1000S162-43) BETWEEN JOISTS EVERY OTHER BAY OVER THE BEARING WALL, CLIP ANGLE EA. END. CANTILEVER SUPPORTING ONE STORY + ROOF PER AISI S230; OTHER CONDITIONS PER PLAN. N.T.S.