Preview of cfs roof truss at exterior wall detail. The DWG is fully editable.

Text on the drawing

15/32" WSP ROOF SHEATHING, #8 SCREWS @ 6" / 12" O.C. PRE-ENGINEERED CFS TRUSSES @ 24" O.C. FASCIA TRACK & VENTED SOFFIT TRUSS HEEL: #10 SCREWS PER TRUSS MFR. TRUSS TIE-DOWN CLIP EA. TRUSS, (4) #10 TO TRUSS, (4) #10 TO STUD 600S162-43 STUDS @ 24" O.C. W/ 600T125-43 TOP TRACK TRUSS DESIGN, BRACING AND CONNECTIONS BY TRUSS MFR. (AISI S240 CH. E; DEFERRED SUBMITTAL). TRUSSES BEAR DIRECTLY OVER STUDS, OR PROVIDE A LOAD DISTRIBUTION MEMBER AT THE TOP TRACK. N.T.S.