TYPDETAIL

Home / Cold-Formed Steel

CFS Floor Opening - Header and Trimmer Joists Detail - typical cold-formed steel detail drawing, DWG
Preview of cfs floor opening - header and trimmer joists detail. The DWG is fully editable.

Text on the drawing

OPENING 8'-0" MAX. 4'-0" MAX. TRIMMER: JOIST + TRACK NESTED (BOXED), #10 @ 24" O.C. HEADER: JOIST + TRACK NESTED (BOXED) EA. END OF OPENING L2X2X54 MIL CLIP X JOIST DEPTH LESS 1/2", (4) #10 EA. LEG, EA. TAIL JOIST (2) CLIP ANGLES, HEADER TO TRIMMER, (4) #10 EA. LEG 1000S162-54 JOISTS @ 16" O.C. FOR FLOOR OPENINGS TO 4'-0" X 8'-0" (STAIR, CHASE), 40 PSF LIVE LOAD. LARGER OPENINGS PER PLAN. SCREW SUBFLOOR TO HEADERS AND TRIMMERS AT 6" O.C. ALL AROUND THE OPENING. N.T.S.

More cold-formed steel details

CFS Floor Joist at Foundation Wall Detail - DWG drawing

CFS Floor Joist at Foundation Wall Detail

CFS Continuous Joist over Interior Bearing Wall Detail - DWG drawing

CFS Continuous Joist over Interior Bearing Wall Detail

CFS Lapped Joists over Interior Bearing Wall Detail - DWG drawing

CFS Lapped Joists over Interior Bearing Wall Detail

CFS Cantilevered Floor Joist at Exterior Wall Detail - DWG drawing

CFS Cantilevered Floor Joist at Exterior Wall Detail

CFS Floor Joist Blocking and Strap Bridging Detail - DWG drawing

CFS Floor Joist Blocking and Strap Bridging Detail

CFS Box Header with Jack and King Studs Detail - DWG drawing

CFS Box Header with Jack and King Studs Detail

CFS Roof Rafter at Exterior Wall - Eave Detail - DWG drawing

CFS Roof Rafter at Exterior Wall - Eave Detail

CFS Roof Truss at Exterior Wall Detail - DWG drawing

CFS Roof Truss at Exterior Wall Detail