TYPDETAIL

Home / Cold-Formed Steel

CFS Partition Bracing Above Ceiling Detail - typical cold-formed steel detail drawing, DWG
Preview of cfs partition bracing above ceiling detail. The DWG is fully editable.

Codes and approvals referenced

ASCE 7

Text on the drawing

STRUCTURE ABOVE 362S125-33 DIAGONAL BRACE @ 48" O.C., 45 DEG. MAX., ALTERNATE SIDES; (2) #8 SCREWS TO TRACK & STUD CLIP ANGLE W/ P.A.F. TO STRUCTURE, (2) #8 TO BRACE 362T125-33 TOP TRACK, 6" MIN. ABOVE CEILING SUSPENDED CEILING EA. SIDE 5/8" GYPSUM BOARD TO 6" ABOVE CEILING 362S125-33 STUDS @ 16" O.C. BRACES FOR 5 PSF PARTITION LOAD AND SEISMIC (ASCE 7 CH. 13); PARTITION TO 12'-0", PLENUM TO 6'-0". DO NOT BRACE PARTITIONS TO THE CEILING GRID IN SDC D-F. KEEP BRACES CLEAR OF DUCTS. N.T.S.