Text on the drawing
5/8" TYPE X GYPSUM BOARD SCREWED TO STUDS 3 1/2" SOUND ATTENUATION BATTS, FULL CAVITY RESILIENT CHANNEL (RC-1) @ 24" O.C. HORIZ., OPEN FLANGE UP, #8 SCREW TO EA. STUD 5/8" TYPE X GYPSUM BOARD SCREWED TO CHANNELS ONLY (1" TYPE S SCREWS BETWEEN STUDS) FIRST CHANNEL 2" ABOVE FLOOR STC 50 CLASS, 1-HOUR ASSEMBLY. DO NOT SHORT-CIRCUIT THE CHANNEL: NO BOARD SCREWS INTO STUDS, NO CABINETS OR BASE FASTENED THROUGH THE CHANNEL SIDE. SEAL PENETRATIONS W/ ACOUSTICAL SEALANT. 362T125-33 TRACK ON (2) BEADS ACOUSTICAL SEALANT, P.A.F. @ 24" O.C. 1/4" GAP W/ ACOUSTICAL SEALANT EA. SIDE N.T.S.