Text on the drawing
12" CLR. (VARIES) 16" O.C. 250S125-33 STUDS @ 16" O.C. EA. ROW GYPSUM BOARD GUSSET 12" DEEP (OR STUD) CROSS BRACE @ 48" O.C. VERT., (2) #8 EA. END WASTE STACK 5/8" GYPSUM BOARD (MOISTURE- RESISTANT AT WET SIDE) CHASE WALL TO 12'-0" HIGH W/ BRACES AT 48" O.C. VERTICALLY ON EVERY STUD PAIR. GROMMET PIPES AT STUD PUNCHOUTS; ISOLATE COPPER FROM STEEL. FIRESTOP PENETRATIONS AT RATED WALLS. N.T.S.