Text on the drawing

CFS STUD PER PLAN (1) #10 S.M.S. EA. FLANGE, EA. END (BOTH SIDES OF STUD) TRACK, SAME DEPTH / GAUGE AS STUD U.N.O., SEATED TIGHT TRACK ANCHORS PER PLAN STUD SEATED WITHIN 1/8" OF TRACK WEB (AISI S240). SCREWS SELF-DRILLING, 3 THREADS MIN. BEYOND STEEL, 3/8" MIN. EDGE DISTANCE. HEAVIER CONNECTIONS (SHEAR WALL / HOLD-DOWN) PER PLAN. 3" = 1'-0"