Control Joints - Gypsum Board Partition and Stucco Detail - typical cold-formed steel detail drawing, DWG
Preview of control joints - gypsum board partition and stucco detail. The DWG is fully editable.

Codes and approvals referenced

ASTM C1063

Text on the drawing

A - GYPSUM BOARD PARTITION DOUBLE STUDS, 1/2" GAP, NOT FASTENED TOGETHER VINYL OR ZINC CONTROL JOINT (NO. 093), BOARD HELD BACK 1/4" EA. SIDE B - CEMENT PLASTER (STUCCO) DOUBLE STUDS; SHEATHING & LATH CUT AT JOINT 2-PIECE EXPANSION JOINT (NO. 40) WIRED TO CUT LATH; WRB & 6" FLASHING STRIP CONT. BEHIND GYPSUM BOARD: JOINTS AT 30'-0" O.C. MAX., AT DOOR HEAD CORNERS, AND AT STRUCTURAL MOVEMENT JOINTS. STUCCO: PANELS 144 SQ. FT. AND 18'-0" MAX., LENGTH / WIDTH 2.5 MAX. (ASTM C1063). RATED WALLS: LISTED JOINT. N.T.S.

More cold-formed steel details

CFS Floor Joist at Foundation Wall Detail - DWG drawing

CFS Floor Joist at Foundation Wall Detail

CFS Continuous Joist over Interior Bearing Wall Detail - DWG drawing

CFS Continuous Joist over Interior Bearing Wall Detail

CFS Lapped Joists over Interior Bearing Wall Detail - DWG drawing

CFS Lapped Joists over Interior Bearing Wall Detail

CFS Cantilevered Floor Joist at Exterior Wall Detail - DWG drawing

CFS Cantilevered Floor Joist at Exterior Wall Detail

CFS Floor Joist Blocking and Strap Bridging Detail - DWG drawing

CFS Floor Joist Blocking and Strap Bridging Detail

CFS Box Header with Jack and King Studs Detail - DWG drawing

CFS Box Header with Jack and King Studs Detail

CFS Roof Rafter at Exterior Wall - Eave Detail - DWG drawing

CFS Roof Rafter at Exterior Wall - Eave Detail

CFS Roof Truss at Exterior Wall Detail - DWG drawing

CFS Roof Truss at Exterior Wall Detail