Semi-Recessed Fire Extinguisher Cabinet in Metal Stud Wall Detail - typical cold-formed steel detail drawing, DWG
Preview of semi-recessed fire extinguisher cabinet in metal stud wall detail. The DWG is fully editable.

Codes and approvals referenced

CBC 11B

Text on the drawing

METAL CABINET W/ GLASS PANEL DOOR, SEMI-RECESSED FIRE EXTINGUISHER (N.I.C.) 5/8" TYPE X GYP. BD. EA. SIDE JAMB STUDS @ OPENING, TRACK HEAD & SILL AT RATED WALLS USE FIRE-RATED CABINET OR BOX OUT BACK W/ GYP. BD. TO MATCH WALL RATING. MOUNT SO HANDLE IS 48" MAX. A.F.F. (CBC 11B-308); PROJECTION 4" MAX. INTO PATH OF TRAVEL. N.T.S.