Codes and approvals referenced
Text on the drawing
(4) #12 GA. SPLAY WIRES @ 90° TO EA. OTHER, 45° MAX. FROM CEILING PLANE COMPRESSION STRUT AT EA. SPLAY WIRE GROUP, SIZED FOR LENGTH #12 GA. HANGER WIRES @ 4'-0" O.C., 3 TIGHT TURNS, 1:6 MAX. OUT OF PLUMB HEAVY-DUTY MAIN RUNNERS 2" MIN. CLOSURE ANGLE; GRID ATTACHED AT 2 ADJ. WALLS, 3/4" CLR. AT OTHERS PER ASTM E580 / ASCE 7 13.5.6: BRACING GROUPS @ 12'-0" O.C. EA. WAY, FIRST WITHIN 6'-0" OF WALLS. OVER 2500 SQ. FT.: SEISMIC SEPARATION JOINTS. 144 SQ. FT. MAX. SURROUNDED BY WALLS: EXEMPT. 3/8" = 1'-0"